A door contact sensor reports whether a door is open or closed, using a magnet on the door and a reed switch on the frame. Access control systems use it to confirm that a door actually closed, to raise a held-open alarm and to re-arm the door after a valid entry.
A reader decides whether a door may open. The contact tells the system what the door did next, and that difference is where most useful diagnostics come from.
Wiring and supervision
The switch is a simple dry contact, wired to a zone input on the controller or panel. An end-of-line resistor at the sensor lets the controller tell an open door from a cut wire. Mount the magnet within the sensor’s stated gap and align it so a settling frame does not report a false opening.
What the contact enables
With a contact, a door can report forced entry, held open too long and unauthorized propping. Without one, a reader cannot tell whether its release worked, and a door that fails to latch goes unnoticed. The contact is also what lets a door re-lock correctly after a valid entry.